ikea_vindriktning_esphome
Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revision | |||
| ikea_vindriktning_esphome [2023/08/18 08:46] – benoitb | ikea_vindriktning_esphome [2023/08/18 08:54] (current) – benoitb | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| ====== Ikea Vindriktning, | ====== Ikea Vindriktning, | ||
| - | L' | + | The aim is to create an air quality measurement device that iseasily integrated into Home Assistant. |
| - | Liste des courses: | + | Shopping list: |
| - | * Ikea Vindriktning | + | * Ikea Vindriktning, PM2.5 sensor, case, LED, off-line controler |
| * https:// | * https:// | ||
| - | * Capteur de température, pression, humidité: bme280 | + | * Temperature, pressure, humidity sensor: bme280 3.3v version |
| * https:// | * https:// | ||
| - | * Capteur de pollution | + | * VOX pollution sensor: sgp40 |
| * https:// | * https:// | ||
| * ESP32-S2 mini | * ESP32-S2 mini | ||
| * https:// | * https:// | ||
| - | * Un peu de câble et de quoi souder | + | * Some cables and tools to solder |
| - | Le schéma de connexion: | + | Wiring schematic: |
| {{:: | {{:: | ||
| - | Une fois soudé: | + | Once soldered: |
| {{:: | {{:: | ||
| - | Les soudures sur la PCB d' | + | Solder points on the IKA stock PCB: |
| {{:: | {{:: | ||
| - | Pour l'installation | + | Final installation: |
| {{:: | {{:: | ||
| - | Les commentaires: | + | Comments: |
| - | * En vert, le Wemos S2 Mini est juste calé là, il ne bouge pas. Il est placé en bas pour gêner au minimum le flux d'air du capteur | + | * In green, the Wemos S2 Mini is just slotted there. It's a tight fit so it doesn't move. I placed it under the fan not to disturb airflow around the PM1006 |
| - | * En bleu, j'ai fait une petite découpe du plastique à la pince coupante pour laisser passer les câbles. | + | * In blue, I cut a piece of the plastic wall to let the cables pass. |
| - | * En rouge j'ai fixé les capteurs de part et d' | + | * In red, I sticked the sensors on each side of the case as close as possible to the venting grill. I used 3M VHB double sided tape. |
| - | Le code YAML pour ESPHome: | + | YAML configuration for ESPHome: |
| < | < | ||
| esphome: | esphome: | ||
ikea_vindriktning_esphome.1692348402.txt.gz · Last modified: 2023/08/18 08:46 by benoitb